- FAQ > Controllers > Programmable Controllers MELSEC > Network related products
FAQ
Keyword Search
FAQ within [ Network related products ]
-
QJ71E71-100's compatibility with the automatic cable type (straight or cross) recognizing function
QJ71E71-100 does not support the AutoMDI/MDI-X function (automatic cable type (straight or cross) recognizing feature). More Details >>
- No:22976
- Release Date:2018/09/03 17:31
-
Number of remote registers assigned to a remote I/O station
For "Remote Net(Ver.2 Mode)", the number of remote I/O's remote registers (RWw, RWr) is "0 Point". More Details >>
- No:22973
- Release Date:2018/09/03 17:31
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
-
Difference between QJ61BT11 and QJ61BT11N
QJ61BT11N supports Version 2 (expanded cyclic setting), the setting for refreshing/forced clearing a slave station data when the switch on a programmable con... More Details >>
- No:22964
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:16
-
Parameter setting of CC-Link IE Field Network
No, you do not have to set the network range assignment parameters for slave stations. By setting the network range assignment parameters for a master statio... More Details >>
- No:23066
- Release Date:2018/09/03 17:31
-
How to check the error history of the QJ71C24N with GX Developer
You can check the error history in the module detailed information in the system monitor of GX Developer. More Details >>
- No:23064
- Release Date:2018/09/03 17:31
-
Limitation on the number of MELSOFT products that can be connected with the QJ71E71
In the TCP/IP connection, you can connect up to 17 MELSOFT products at the same time using a dedicated connection for system and the connections for users 1 ... More Details >>
- No:23063
- Release Date:2018/09/03 17:31
-
Mixing line topologies with star topologies in the CC-Link IE Field Network
Line topologies and star topologies can be mixed. More Details >>
- No:23059
- Release Date:2018/09/03 17:31
-
Unit of receive data used by the QJ71C24N series pre-defined protocol support function
The fixed data is used for specific codes and character strings such as a command. Setting a device is not required. More Details >>
- No:23049
- Release Date:2018/09/03 17:31
81-90 of Total 110