Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
-
Compatibility of the high speed data logger module's report function with 64-bit Excel2010
The high speed data logger module's report function does not support 64-bit Excel2010. More Details >>
- No:22897
- Release Date:2018/09/03 17:30
-
Multiplication in the Structured Text
Basic arithmetic operations cannot be performed on unsigned words. Please assign the multiplier to a signed (single/double) word. More Details >>
- No:22886
- Release Date:2018/09/03 17:30
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
-
Reference manuals for programming for FX programmable controllers in ST language
The following shows the manuals for programming in ST language. - GX Works2 Beginner's Manual (Structured Project) - GX Works2 Version 1 Operating Manual... More Details >>
- No:22959
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:16
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
-
Function blocks of GX Developer and GX Works2
The same function blocks can be created and used. More Details >>
- No:22887
- Release Date:2018/09/03 17:30
-
Program by program difference in comments on display
There are two types of device comments: "global device comment" and "local device comment". Device comments can be displayed in the ladder editor and Zoom... More Details >>
- No:22868
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:40