For GX Developer, a connection via an A series Ethernet interface module allows communication only within the same segment. Via a router, it is impossible to... More Details >>
- No:22902
- Release Date:2018/09/03 17:30
-
GX Developer's compatibility with QnUDVCPU
GX Developer does not support QnUDVCPU. Please use GX Works2 instead. More Details >>
- No:22885
- Release Date:2018/09/03 17:30
-
Writing LJ71C24 modules' parameters using GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22912
- Release Date:2018/09/03 17:30
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30
-
Multiplication in the Structured Text
Basic arithmetic operations cannot be performed on unsigned words. Please assign the multiplier to a signed (single/double) word. More Details >>
- No:22886
- Release Date:2018/09/03 17:30
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
-
Accessing a QnA compatible Ethernet interface module via a router using GX Developer
For GX Developer, a connection via a QnA compatible Ethernet interface module allows communication only within the same segment. Via a router, it is impossib... More Details >>
- No:22845
- Release Date:2018/09/03 17:30
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
-
A message that says "A T/C coil with the same No. exists."
It is a confirmation message telling a user that there is a device, T or C, that has become a duplicated coil in the same program and the coil is given the s... More Details >>
- No:22859
- Release Date:2018/09/03 17:30