Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
-
Special auxiliary relay which is always on (MELSEC-F)
M8000 More Details >>
- No:22258
- Release Date:2018/08/30 13:48
-
Turning on a bit in the data register
In the FX3U/FX3UC series, the bit specification of the data register is possible. (Example) D0.7→7th bit in D0 For the other types of MELSEC-F programmable... More Details >>
- No:22275
- Release Date:2018/08/30 13:48
-
I cannot convert a circuit created with GX Developer.
When the conversion is executed, online change is automatically executed.When the online change at the upper right section of the setting in "Options" of "To... More Details >>
- No:22958
- Release Date:2018/09/03 17:31
-
FX3U-ENET-ADP connectable programmable controllers in the MELSEC-F series
The FX3U-ENET-ADP can be connected to the FX3G/FX3GC series (both Ver. 2.00 or later) and the FX3U/3UC series (both Ver. 3.10 or later). Products which are ... More Details >>
- No:24706
- Release Date:2019/02/27 09:00
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48