FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > Engineering Software
FAQ
Keyword Search
FAQ within [ Engineering Software ]
-
MX Component Version 4's compatibility with Visual C++ 6.0
MX Component Version 4 does not support Visual C++ 6.0. More Details >>
- No:22913
- Release Date:2018/09/03 17:30
-
If MX Sheet that supports Excel2010 is installed, the data can be used as they are. More Details >>
- No:22892
- Release Date:2018/09/03 17:30
-
GX Works2's compatibility with the ACPU modules
GX Works2 does not support the ACPU modules.Use GX Developer for the ACPU modules.GX Developer is included on the CD-ROM of GX Works2.For the installation pr... More Details >>
- No:22873
- Release Date:2018/09/03 17:30
-
Index modification in function blocks
Index modification cannot be used for labels. To set index modification, use actual devices as the target devices. More Details >>
- No:22930
- Release Date:2018/09/03 17:30
-
List of registers assigned to the labels set using GX Works2
To display a list of registers assigned to labels, check [Find Label Definition] and [Display all items] in the [Condition Setting] tab in the [Cross Refere... More Details >>
- No:22923
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:42
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
-
MX Component Version 4's compatibility with Visual Basic 6.0
MX Component Version 4 does not support Visual Basic 6.0. More Details >>
- No:22884
- Release Date:2018/09/03 17:30
-
A message that says "A T/C coil with the same No. exists."
It is a confirmation message telling a user that there is a device, T or C, that has become a duplicated coil in the same program and the coil is given the s... More Details >>
- No:22859
- Release Date:2018/09/03 17:30
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30
-
Required setting for the display of hidden comments
Device comments can be displayed in the ladder editor and Zoom editor windows. Select [View] -> [Comment] from the menu to display the comments. More Details >>
- No:22875
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:40