Communications using the built-in USB port of the FX3 series
When you connect the built-in USB port of the FX3 series to the personal computer for the first time, you need to install the USB driver into the personal co... More Details >>
- No:22273
- Release Date:2018/08/30 13:48
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
-
Assignment of input/output numbers (MELSEC-F series)
Octal numbers are assigned as input/output numbers for the MELSEC-F series. The octal number system uses the digits from 0 to 7 → from 10 to 17 → from 20 to... More Details >>
- No:24868
- Release Date:2019/04/15 08:06
-
How to install a USB driver in Windows XP
For how to install a USB driver in Windows XP, refer to the following procedure. (1) Connect a personal computer and a programmable controller CPU with a ... More Details >>
- No:22933
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:59
-
Automatically assigned devices in GX Works2
Yes.Beginning with the device in the "Device/Label Automatic-Assign Setting" window, devices are assigned in descending order (from the greatest device numbe... More Details >>
- No:22846
- Release Date:2018/09/03 17:30
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22
-
Turning on/off a specified bit of a word device (D) using a simple program
In the FX programmable controllers (FX3U/FX3UC series), a bit in a word device can be specified in a program. It can be specified as "word device (D only) + ... More Details >>
- No:25011
- Release Date:2019/04/23 11:13
-
Maximum number of characters in a comment that can be transferred to a FX3U series
As project data, up to 32 one-byte characters (16 two-byte characters) can be input to each global device comment. However, the maximum number of characters ... More Details >>