FAQ within [ Engineering Software ]
-
Identifying an SFC program block in execution
Specify a block in the cross reference list and search it. (For block 1, search BL1, for example.) More Details >>
- No:22907
- Release Date:2018/09/03 17:30
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
-
MX Component Version 4's compatibility with Visual Basic 6.0
MX Component Version 4 does not support Visual Basic 6.0. More Details >>
- No:22884
- Release Date:2018/09/03 17:30
-
Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
-
Accessing a QnA compatible Ethernet interface module via a router using GX Developer
For GX Developer, a connection via a QnA compatible Ethernet interface module allows communication only within the same segment. Via a router, it is impossib... More Details >>
- No:22845
- Release Date:2018/09/03 17:30
-
Writing QJ71C24N's parameters in GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22872
- Release Date:2018/09/03 17:30
-
CW Workbench can be purchased from Mitsubishi Electric. We also accept license applications. More Details >>
- No:22880
- Release Date:2018/09/03 17:30
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30