FAQ within [ Engineering Software ]
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
-
How to check the scan time (MELSEC-F series)
The present scan time is stored in D8010. Monitor the valueusing a programming tool such as GX Works2 and GX Developer. More Details >>
- No:24685
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:07
-
Special auxiliary relay which is always on (MELSEC-F)
M8000 More Details >>
- No:22258
- Release Date:2018/08/30 13:48
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
Language selection function of GX Works2
You can select the language to be used in project data (device comments, statements, notes, etc.).With this function, you can select the language to be used ... More Details >>
- No:22936
- Release Date:2018/09/03 17:30
-
Transferring/editing programs in the previous FX programmable controllers using GX Works2
The earlier series of the FX programmable controllers are compatible with the latest series of the FX programmable controllers. More Details >>
- No:25012
- Release Date:2019/04/23 11:16
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
-
I cannot select [Transfer Setup] in GX Developer because it is displayed in gray.
You cannot select the item while the programmable controller is being monitored. Execute [Close all windows] of [Window] from the tool bar, and check if Tra... More Details >>
- No:22955
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:11
-
An error (error code: F1028) occurs when compilation is executed in GX Works2.
You have used the device set as the automatic assignment device for labels in the program. Change the device with the one out of the range or change the auto... More Details >>
- No:22954
- Release Date:2018/09/03 17:30