Changing the time of a programmable controller by using the clock data write instruction (TWR)
When changing the time by using the clock data write instruction (TWR), the control of M8015 (Clock stop/adjustment) is not required. * When the clock data... More Details >>
- No:22266
- Release Date:2018/08/30 13:48
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35
-
Counting of a built-in high-speed counter
Check that the RST instruction ofthe high-speed counter is not executed whilethe program is running. Forthe high-speed counter which supports the external r... More Details >>
- No:24787
- Release Date:2019/02/28 09:06
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
-
Reflecting the changes in the communication setting
Power off and on the programmable controller again after the communication setting is changed. More Details >>
- No:25006
- Release Date:2019/04/23 11:11
-
Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
-
FX3U-ENET-ADP connectable programmable controllers in the MELSEC-F series
The FX3U-ENET-ADP can be connected to the FX3G/FX3GC series (both Ver. 2.00 or later) and the FX3U/3UC series (both Ver. 3.10 or later). Products which are ... More Details >>
- No:24706
- Release Date:2019/02/27 09:00
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30