Transferring/editing programs in the previous FX programmable controllers using GX Works2
The earlier series of the FX programmable controllers are compatible with the latest series of the FX programmable controllers. More Details >>
- No:25012
- Release Date:2019/04/23 11:16
-
Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
-
Assignment of input/output numbers (MELSEC-F series)
Octal numbers are assigned as input/output numbers for the MELSEC-F series. The octal number system uses the digits from 0 to 7 → from 10 to 17 → from 20 to... More Details >>
- No:24868
- Release Date:2019/04/15 08:06
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
Checking the amount of free space of the memory in GX Developer/GX Works2
Select [Tool] -> [Confirm Memory Size] to check the amount. More Details >>
- No:22851
- Release Date:2018/09/03 17:30
-
Displaying devices in GX Works2
Yes. The device use list also displays the devices used for specifying digits, such as "K4M0" (including M1, M2, or others). More Details >>
- No:22942
- Release Date:2018/09/03 17:30
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33