FAQ within [ Engineering Software ]
-
It is impossible to access the GOT via a universal model QCPU module. More Details >>
- No:22906
- Release Date:2018/09/03 17:30
-
Compatibility between MX Component Version 3 and 4
Applications created using MX Component Version 3 can be used, as they are, on a personal computer on which MX Component Version 4 is installed. MX Component... More Details >>
- No:22839
- Release Date:2018/09/03 17:30
-
Function blocks of GX Developer and GX Works2
The same function blocks can be created and used. More Details >>
- No:22887
- Release Date:2018/09/03 17:30
-
Using send FBs/receive FBs simultaneously
If multiple send FBs/receive FBs are simultaneously executed, the FBs do not function properly.When there are multiple send FBs, do not execute two or more s... More Details >>
- No:22893
- Release Date:2018/09/03 17:30
-
Accessing an A series Ethernet interface module via a router using GX Developer
For GX Developer, a connection via an A series Ethernet interface module allows communication only within the same segment. Via a router, it is impossible to... More Details >>
- No:22902
- Release Date:2018/09/03 17:30
-
Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956