- FAQ > Controllers > Programmable Controllers MELSEC > Engineering Software
FAQ
Keyword Search
FAQ within [ Engineering Software ]
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
-
I cannot convert a circuit created with GX Developer.
When the conversion is executed, online change is automatically executed.When the online change at the upper right section of the setting in "Options" of "To... More Details >>
- No:22958
- Release Date:2018/09/03 17:31
-
Displaying devices in GX Works2
Yes. The device use list also displays the devices used for specifying digits, such as "K4M0" (including M1, M2, or others). More Details >>
- No:22942
- Release Date:2018/09/03 17:30
-
Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
-
MX Component Version 4's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22844
- Release Date:2018/09/03 17:30
-
Storage media of a project file
The project file written in the write-inhibited media, such as FD, CD-R, or CD-RW, cannot be read. (Condition: The standard Windows status without CD-R/RW w... More Details >>
- No:25007
- Release Date:2019/04/23 11:11
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
51-60 of Total 129