FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > Engineering Software
FAQ
Keyword Search
FAQ within [ Engineering Software ]
-
Opening function block and Structured Text projects in GX Works2
The project can be read by selecting "Open other project" in GX Works2. - Function names for the GX Developer's Structured Text are different from those of ... More Details >>
- No:22864
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:28
-
Local device comments can be read if the comment file in which the local device comments are stored is written to the CPU module. More Details >>
- No:22869
- Release Date:2018/09/03 17:30
-
Using GX Logviewer's realtime monitor function on multiple personal computers
Up to two realtime monitor windows can be used for monitoring.If each of two personal computers monitors one monitor window, two personal computers can be co... More Details >>
- No:22881
- Release Date:2018/09/03 17:30
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
-
How to paste values in the device batch monitor window into an Excel sheet
Copy and paste operations cannot be carried out for values displayed in the device batch monitor window. To paste the values into an Excel sheet, read the d... More Details >>
- No:22888
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:54
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30
-
Copying statements and notes of GX Developer
Notes and statements are batch managed in the program file. It is impossible to copy notes and statements alone. More Details >>
- No:22853
- Release Date:2018/09/03 17:30
-
GX Works2's compatibility with the ACPU modules
GX Works2 does not support the ACPU modules.Use GX Developer for the ACPU modules.GX Developer is included on the CD-ROM of GX Works2.For the installation pr... More Details >>
- No:22873
- Release Date:2018/09/03 17:30
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
-
Required setting for the display of hidden comments
Device comments can be displayed in the ladder editor and Zoom editor windows. Select [View] -> [Comment] from the menu to display the comments. More Details >>
- No:22875
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:40
51-60 of Total 129