Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
-
Function blocks and PLC type change
Yes. Execute conversion/compilation after changing the PLC type. More Details >>
- No:22931
- Release Date:2018/09/03 17:30
-
Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
-
The number of FB definitions created in a project has no limitation. More Details >>
- No:22900
- Release Date:2018/09/03 17:30
-
A message that says "A T/C coil with the same No. exists."
It is a confirmation message telling a user that there is a device, T or C, that has become a duplicated coil in the same program and the coil is given the s... More Details >>
- No:22859
- Release Date:2018/09/03 17:30
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773