List of registers assigned to the labels set using GX Works2
To display a list of registers assigned to labels, check [Find Label Definition] and [Display all items] in the [Condition Setting] tab in the [Cross Refere... More Details >>
- No:22923
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:42
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
-
Writing comments into a programmable controller
Make a space for comments in the parameter setting of the programmable controller with GX Developer.To write the created comments into a programmable control... More Details >>
- No:22962
- Release Date:2018/09/03 17:31
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
-
Accessing a QnA compatible Ethernet interface module via a router using GX Developer
For GX Developer, a connection via a QnA compatible Ethernet interface module allows communication only within the same segment. Via a router, it is impossib... More Details >>
- No:22845
- Release Date:2018/09/03 17:30
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
-
Compatibility of the high speed data logger module's report function with 64-bit Excel2010
The high speed data logger module's report function does not support 64-bit Excel2010. More Details >>
- No:22897
- Release Date:2018/09/03 17:30
-
Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
-
When a personal computer (GX Works2) is connected to the RS-232C port of a programmable controller, communications between the personal computer and the prog... More Details >>
- No:24782
- Release Date:2019/02/27 16:10
-
Index modifier of bit devices in the FX3G series
The FX3G series does not support the index modifier for the bit devices. The FX3U/FX3UC series supports this function. More Details >>
- No:24959
- Release Date:2019/04/18 14:35