- FAQ > Controllers > Programmable Controllers MELSEC > Engineering Software
FAQ
Keyword Search
FAQ within [ Engineering Software ]
-
How to copy a comment in GX Works2
1. Right-click the file name of a device comment to be copied, and select "Copy" from the menu.2. Right-click the file name of a device comment to which the ... More Details >>
- No:22939
- Release Date:2018/09/03 17:30
-
MX Component Version 4's compatibility with Visual Basic .NET 2003
MX Component Version 4 does not support Visual Basic .NET 2003. More Details >>
- No:22899
- Release Date:2018/09/03 17:30
-
Writing comments into a programmable controller
Make a space for comments in the parameter setting of the programmable controller with GX Developer.To write the created comments into a programmable control... More Details >>
- No:22962
- Release Date:2018/09/03 17:31
-
MX Component Version 4's compatibility with Visual C++ 6.0
MX Component Version 4 does not support Visual C++ 6.0. More Details >>
- No:22913
- Release Date:2018/09/03 17:30
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
-
I cannot select [Transfer Setup] in GX Developer because it is displayed in gray.
You cannot select the item while the programmable controller is being monitored. Execute [Close all windows] of [Window] from the tool bar, and check if Tra... More Details >>
- No:22955
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:11
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30