Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
-
Writing QJ71C24N's parameters in GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22872
- Release Date:2018/09/03 17:30
-
How to paste values in the device batch monitor window into an Excel sheet
Copy and paste operations cannot be carried out for values displayed in the device batch monitor window. To paste the values into an Excel sheet, read the d... More Details >>
- No:22888
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:54
-
Identifying an SFC program block in execution
Specify a block in the cross reference list and search it. (For block 1, search BL1, for example.) More Details >>
- No:22907
- Release Date:2018/09/03 17:30
-
Displaying the next page in the Print Preview window
It is only possible to preview the first page to verify the print size and form. More Details >>
- No:22924
- Release Date:2018/09/03 17:30
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
-
Externally switching the operating status of a programmable controller
On the Project view of the Navigation window, select "Parameter" → "PLC Parameter" using GX Works2 (or GX Developer). Click the "PLC System(1)" tab, and set ... More Details >>
- No:24768
- Release Date:2019/02/27 15:01
-
Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08