Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
-
MX Component Version 4's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22844
- Release Date:2018/09/03 17:30
-
MX Sheet Version 2's compatibility with 64-bit Windows 7
Yes. More Details >>
- No:22866
- Release Date:2018/09/03 17:30
-
Writing comments into a programmable controller
Make a space for comments in the parameter setting of the programmable controller with GX Developer.To write the created comments into a programmable control... More Details >>
- No:22962
- Release Date:2018/09/03 17:31
-
Accessing an A series Ethernet interface module via a router using GX Developer
For GX Developer, a connection via an A series Ethernet interface module allows communication only within the same segment. Via a router, it is impossible to... More Details >>
- No:22902
- Release Date:2018/09/03 17:30
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
-
Time out error in the communication test of MX Component
The possible causes are as follows. - Incorrect setting with a personal computer or an Ethernet interface module Check the IP address, network number, sta... More Details >>
- No:22934
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:49