Reading a project in another format
To open a project created with GX Developer, select [Project]-> [Import file]-> [Import from xxxx format file] from the menu in GX Works2. More Details >>
- No:22952
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:56
-
The cross reference window is not displayed.
Select [View]-> [Cross reference window] from the menu in GX Developer to display the cross reference window. More Details >>
- No:22951
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:54
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
-
List of registers assigned to the labels set using GX Works2
To display a list of registers assigned to labels, check [Find Label Definition] and [Display all items] in the [Condition Setting] tab in the [Cross Refere... More Details >>
- No:22923
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:42
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
-
Installing MX Component Version 3 and 4
No, please install only either of the two. More Details >>
- No:22841
- Release Date:2018/09/03 17:30
-
Required setting for the display of hidden comments
Device comments can be displayed in the ladder editor and Zoom editor windows. Select [View] -> [Comment] from the menu to display the comments. More Details >>
- No:22875
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:40
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
-
Compatibility between GX IEC Developer and GX Developer
GX IEC Developer and GX Developer are different products. They are not compatible. Projects created using GX IEC Developer can neither be opened in GX Develo... More Details >>
- No:22860
- Release Date:2018/09/03 17:30