By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
-
Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
-
Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
-
Regarding input of Differential Driver Output Type
It does not. The built-in high-speed counter function of the FX5U/FX5UC CPU module does not support DC5V input. DC5V input can be achieved by adding BUS con... More Details >>
- No:39350
- Release Date:2023/01/12 17:09
- Update:2025/03/07 13:25
-
Regarding the difference of current address (user unit, pulse unit)
The difference between the current address (user unit) and the current address (pulse unit) is as follows: The current address (user unit) becomes the unit ... More Details >>
- No:39357
- Release Date:2023/02/15 13:05
-
From the [Module] tab ⇒ [Module FB] in the [Element Selection] window of GX Works3, drag and drop the Module FB you want to use to the program editor. More Details >>
- No:44606
- Release Date:2024/11/28 16:11
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
-
Regarding Statement and Note Types
PLC :it is written to the CPU module and consumes the number of steps. ・Without character - 3 steps ・With character : 4 + (Number of characters + 2 + 14) /... More Details >>
- No:40023
- Release Date:2023/08/24 15:39
-
Regarding instructions for converting constants from decimal to hexadecimal
Decimal numbers of up to 4 digits can be converted to hexadecimal numbers using the BCD(P) instruction, and decimal numbers of up to 8 digits can be converte... More Details >>
- No:44352
- Release Date:2024/03/27 15:43