- FAQ > Controllers > Motion Controllers > MELSEC iQ-R Series
FAQ
Keyword Search
MELSEC iQ-R Series
FAQ within [ MELSEC iQ-R Series ]
-
Yes. (1) Absolute system (a) When the software stroke limit is invalid Positioning is carried out in a designated direction by "[Cd.40] ABS direction in deg... More Details >>
-
Refer to "b2: Command in-position flag" of "[Md.31] Status". More Details >>
-
The rapid stop deceleration time of parameter block is applied.However, when the rapid stop deceleration time is set in the servo program, the value is enabl... More Details >>
-
Torque is limited by the lower set value of "[Pr.17] Torque limit setting value" and "[Cd.22] New torque value/forward new torque value".When the current tor... More Details >>
-
Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>
-
Minor error 197AH (Home position return zero not passed) occurs in the following case:"[St.1066] zero pass" is OFF when the re-movement to the home position ... More Details >>
- No:23560
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program Speed change request CHGV,CHGVS ... More Details >>
- No:23575
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
- No:23551
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Error 2035 (Command frequency error) occurs when the servo amplifier detects a command frequency error. (1) When the command from the controller is the permi... More Details >>
-
Set "[Pr.45] Home position address" of the basic parameters for home position return • Axis 1 to 16: 72+150n, 73+150n • Axis 17 to 32: 1000072+150n, 1000073+... More Details >>