  • Acceleration/deceleration time change

    Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>

    • No:23569
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Minor error 197AH

    Minor error 197AH (Home position return zero not passed) occurs in the following case:"[St.1066] zero pass" is OFF when the re-movement to the home position ... More Details >>

    • No:23560
    • Release Date:2018/09/14 15:09
    • Category: RnMTCPU
  • Major error 093CH

    Major error 093CH occurs when the absolute position is erased.Execute the home position return after checking the batteries of the Motion CPU module and the ... More Details >>