FAQ
FAQAbout Products
- FAQ > Low-voltage Power Distribution Products > Power Management Meters
FAQ
Keyword Search
Power Management Meters
FAQ within [ Power Management Meters ]
-
When the AC waveform distorted due to harmonics, the value changes. (For AC without harmonics, the calculated value will match with the displayed value.) A... More Details >>
- No:22178
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:56
- Category: Electrical Indicators
-
Measurement value different from other measuring instrument (ME96SS series).
In general, in case of measurement by the average method, the waveform including harmonics cause large error. This model uses the RMS value method and measu... More Details >>
- No:22177
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:54
- Category: Electrical Indicators
-
Measuring received energy and the transferred energy (ME96SS series).
It is possible to measure the received energy and the transferred energy separately. More Details >>
- No:22176
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:53
- Category: Electrical Indicators
-
Wiring for only measuring current (ME96SS series).
It is unnecessary. (It is necessary to prepare an auxiliary power supply which supplies power between MA and MB.) More Details >>
- No:22174
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:50
- Category: Electrical Indicators
-
Checking non-displayed digit of active energy (ME96SS series).
Pressing buttons of the “+” and the “-” at the same time on the measurement screen for 2 seconds shifts the unit of active energy as follows. The measured ... More Details >>
- No:22172
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:44
- Category: Electrical Indicators
-
Installation compatibility with ME96NSR (ME96SS series).
They are the same dimensions. (Dimensions of an installation hole is 92 mm in length and width. Install this model two points with mounting brackets.) More Details >>
- No:22160
- Release Date:2018/08/27 16:41
- Category: Electrical Indicators
-
IP protection class (ME96SS series).
In a board installation state, the protection class is equivalent to IP50. This model is not waterproof. More Details >>
- No:22158
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:13
- Category: Electrical Indicators
-
Measurable minimum voltage (ME96SS series).
In case of the input voltage of less than 11 V, the measurement values are as follows: Voltage: 0 V,Power supply: 0 W, Reactive power: 0 var, Apparent pow... More Details >>
- No:22156
- Release Date:2018/08/27 16:41
- Update:2020/04/10 16:08
- Category: Electrical Indicators
-
Availability for special primary current and special primary voltage (ME96SS series).
This model is able to be used under unusual primary current and unusual primary voltage as long as the user sets each value within the selectable range as ... More Details >>
- No:22148
- Release Date:2018/08/27 16:41
- Update:2020/04/10 15:15
- Category: Electrical Indicators
-
Check the measurement values using MODBUS RTU communication
It is possible to check them using the Data Acquisition Software EMU4-SW1. It is available for download without payment from the following Web site. ... More Details >>
- No:37812
- Release Date:2020/04/10 15:10
- Category: Electrical Indicators
21-30 of Total 57