Controllers
FAQ within [ Controllers ]
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding number of expansion adapter connections
The number of expansion adapters varies depending on the type of adapter, and up to six can be connected. ・Analog adapter: Up to 4 ・Communication adapter: ... More Details >>
- No:44966
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding built-in high-speed counter function
The MX-F Model also supports the built-in high-speed counter function. The number of channels is up to 8, and the counter types supported are 1-phase 1-inpu... More Details >>
- No:44980
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio.Example) For Q06HCPU with power-on time ratio of 50... More Details >>
- No:22523
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Local devices are devices which can be independently used for each program.When multiple independent programs are executed, using local devices allows progra... More Details >>
- No:22531
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Usage of PIDCONT instruction in process CPU
No. More Details >>
- No:22536
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Reading file registers simultaneously with the program, parameters, and other data in GX Works2
No. Switch the target memory for PLC Data and read the file registers alone. More Details >>
- No:22616
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
CPU modules that support the File Register Extended Setting
The universal model QCPU modules other than Q00UJCPU support the File Register Extended Setting. More Details >>
- No:22627
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>