FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Transient transmission of the CC-Link IE Controller
Transient transmission is a function that allows communication with programmable controllers in other stations. Communication with programmable controllers i... More Details >>
- No:23016
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The conversion speed is as follows. - High speed: 20 microseconds per channel- Medium speed: 80 microseconds per channel- Low speed: 1 millisecond per channel More Details >>
- No:22776
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Maximum number of connectable modules to LCPU when it is not extended
Up to 10 modules can be connected in the system as a whole except for the power supply module, CPU module, display unit, RS232C adapter, and END cover. Some ... More Details >>
- No:22775
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
MC protocol compatibility of the built-in Ethernet port
The built-in Ethernet port is not compatible with a 4E frame. Use a QnA-compatible 3E frame. More Details >>
- No:22732
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The numbers of POUs and steps of "Allocate Memory for 'Online Change'" in GX Works2
The maximum number of steps that an online change can process at a time is 512. More Details >>
- No:22672
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to change the type of statement in GX Developer
Select [Search/Replace] -> [Replace statement/note type] from the menu and select "Change in PLC". More Details >>
- No:22647
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Difference between Q24DHCCPU-V and Q12DCCPU-V
Hardware specifications are different. For hardware specifications, refer to the following manuals. - MELSEC-Q C Controller Module User's Manual - C Contro... More Details >>
- No:22629
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:41
- Category: MELSEC-Q Series
-
Cause of file register reset by latch clear operation in universal model QCPU
If Latch (1) is set in the device setting of PLC parameter, the contents of file registers are cleared by latch clear operation. Set Latch (2) to maintain t... More Details >>
- No:22584
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:31
- Category: MELSEC-Q Series
-
Is the version of MX Component compatible with Windows 7? Update the software to the version compatible with Windows 7 and then update the driver. For the ... More Details >>
- No:22569
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:50
- Category: MELSEC-Q Series
991-1000 of Total 1123