Controllers
FAQ within [ Controllers ]
-
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio.Example) For Q06HCPU with power-on time ratio of 50... More Details >>
- No:22523
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Including GX Developer in GX Works2
Yes, it does.GX Developer can be installed along with the installation of GX Works2.For more details of the installation procedure, refer to GX Works2 Versio... More Details >>
- No:22506
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Differences between the AJ65SBTB1-16TE and AJ65SBTB1B-16TE1
The following shows the major differences. -AJ65SBTB1-16TE - 1-wire terminal block, 1-common type - Maximum load current: 0.1 A/point -Protection fu... More Details >>
- No:23083
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:16
- Category: Network related products
-
MX Component Version 4's compatibility with Visual Basic 6.0
MX Component Version 4 does not support Visual Basic 6.0. More Details >>
- No:22884
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Use SP.FWRITE instruction to save the data to an SD memory card in CSV format. More Details >>
- No:22727
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Production of Q61P-A1 and Q61P-A2
They have gone out of production. However, Q61P, a succeeding model, can be used in the same way. More Details >>
- No:22655
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series