Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding parameter setting for FX5-CCL-MS
It is possible to set the basic/application settings in a program by selecting the parameter setting method to "Program." Even if set by "program" is select... More Details >>
- No:39367
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the connection between FX5-CCLGN-MS and SLMP-compatible devices
The SLMP communication frames supported by the FX5-CCLGN-MS are 3E and 4E frames. When SLMP communication is performed from an SLMP-compatible device to the... More Details >>
- No:39280
- Release Date:2023/01/12 16:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master module settings
If each master module controls their own CC-Link networks, all master modules can be set as station 0 even though they are controlled by the same CPU. More Details >>
- No:23008
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Parameter settings for a CC-Link master station and local stations
Local stations also need parameter settings. More Details >>
- No:22991
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Ethernet cables for the CC-Link IE Field Network
General-purpose Ethernet cables that meet the 1000BASE-T standard (category 5e or higher) can be used. We recommend double shielded cables. Recommended pro... More Details >>
- No:22989
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:47
- Category: Network related products
-
Terminating resistors for RS-422 communication of QJ71C24N
The resistance value is 330 ohm, 1/4 W. More Details >>
- No:22965
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:33
- Category: Network related products