FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Opening a project in an old version of GX Developer
Products earlier than version 8.58L do not support a project in which the following parameters are set. All the parameters are set to their default values be... More Details >>
- No:22666
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:53
- Category: MELSEC-Q Series
-
Writing LJ71C24 modules' parameters using GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22912
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
A message that says "A T/C coil with the same No. exists."
It is a confirmation message telling a user that there is a device, T or C, that has become a duplicated coil in the same program and the coil is given the s... More Details >>
- No:22859
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Compatibility between MX Component Version 3 and 4
Applications created using MX Component Version 3 can be used, as they are, on a personal computer on which MX Component Version 4 is installed. MX Component... More Details >>
- No:22839
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Difference between L02CPU-P and L02CPU
In L02CPU-P, the general-purpose output of the built-in I/O is source type. In L02CPU, the general-purpose output of the built-in I/O is sink type. More Details >>
- No:22743
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Necessity of terminating resistors in CC-Link communication
No, it is unnecessary. Terminating resistors are only required at both ends of the network. More Details >>
- No:22966
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MX Component Version 4's compatibility with Visual Studio 2010
The initial version and subsequent versions of MX Component Version 4 support Visual Basic and Visual C++ of Visual Studio 2010. More Details >>
- No:22842
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Deleting GX Developer when installing GX Works2
GX Developer does not need deleting when GX Works2 is installed. More Details >>
- No:22670
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Battery life in the universal model QCPU
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio. Example) For Q06UDHCPU with power-on time ratio... More Details >>
- No:22633
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:28
- Category: MELSEC-Q Series
-
Copying device comments in GX Works2
Select a device comment in the project view and select "Copy" from the right-click menu. More Details >>
- No:22950
- Release Date:2018/09/03 17:30
- Category: Engineering Software
1081-1090 of Total 1110