FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Index modification when using extended data register in LCPU
It is not possible to specify index modification to cross over the boundary between the internal user device (D) and the extended data register (D). Change t... More Details >>
- No:22822
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
An error occurs and CPU will stop. Install the END cover and reset the CPU module. More Details >>
- No:22817
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The number of tasks that can be created depends on free space of the work RAM. Execute the following command with shell to check the free space of the work R... More Details >>
- No:22716
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Whether or not device indirect specifications in structured ladder programs are allowed
Indirect specifications with "@" cannot be used in structured ladder programs and the Structured Text. Use indirect specifications in a ladder language program. More Details >>
- No:22697
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Uncheck "Check battery", an item of "Error Check", in the [PLC RAS setting] ([PLC Parameter] -> [PLC RAS setting]). More Details >>
- No:22681
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:12
- Category: MELSEC-Q Series
-
Execution in a multi task environment
The QBF_Open ( ) function or mdOpen ( ) function is required for every task. Do not share the PATH acquired using an Open function with other tasks.Also, exe... More Details >>
- No:22678
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to change the type of statement in GX Developer
Select [Search/Replace] -> [Replace statement/note type] from the menu and select "Change in PLC". More Details >>
- No:22647
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series