Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding functional differences from iQ-F Series
Please refer to the below Technical bulletin for the functional differences between the MX-F model and the iQ-F series. [Technical bulletin] ・Differences ... More Details >>
- No:44979
- Release Date:2025/06/18 14:38
- Category: MELSEC MX Controller MX-F Model
-
Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Input Response Frequency Difference between FX5-2HC/ES and Conventional Model (FX3U-2HC)
The input response frequencies of the FX5-2HC/ES and FX3U-2HC differ as shown below. FX5-2HC/ES・・・2MHz FX3U-2HC・・・200kHz More Details >>
- No:44340
- Release Date:2024/03/20 13:31
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Compatibility of the high speed data logger module's report function with 64-bit Excel2010
The high speed data logger module's report function does not support 64-bit Excel2010. More Details >>
- No:22897
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
Difference between redundant systems and the multiple CPU systems
- Redundant systems A redundant system offers improved system reliability, as it consists of two basic systems, each of which includes a CPU module, powe... More Details >>
- No:22609
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:14
- Category: MELSEC-Q Series
-
No. More Details >>
- No:22589
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:42
- Category: MELSEC-Q Series
-
FL-net interface module setting
The auto refresh setting is not required. However, making the setting can reduce communication programs. More Details >>