Reading file registers simultaneously with the program, parameters, and other data in GX Works2
No. Switch the target memory for PLC Data and read the file registers alone. More Details >>
- No:22616
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Reading file registers in the standard RAM
Set Target Memory to "Standard RAM" in the Read from PLC window to select a file register file. More Details >>
- No:22552
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
- Category: MELSEC iQ-R Series
-
How to display the network parameter setting window with GX Works3
"Network Parameter" in GX Works2 is "Module Parameter" of a "network module" in GX Works3. Click the items in the following order to display the setting win... More Details >>
- No:22485
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:55
- Category: MELSEC iQ-R Series
-
Difference between AJ65SBTB1-16DT and AJ65SBTB1-16DT1
Major differences in input specifications are shown below. - AJ65SBTB1-16DT - Rated input current approx. 7 mA - ON voltage/ON current 14 VDC or higher/... More Details >>
- No:23035
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:24
- Category: Network related products
-
"[ ]" in the CC-Link remote I/O modules' model name "AJ65[ ]BT" represents as follows: - None: Standard type - S: Compact type - F: Low profile waterpro... More Details >>
- No:22974
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:12
- Category: Network related products
-
What to do in the case of the error "A default router IP address needs to be set."
When having access bypassing a router, enter only the IP address.The subnet mask pattern is not required to be entered because GX Works2 or GX Developer auto... More Details >>
- No:22605
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:06
- Category: MELSEC-Q Series
-
Regarding functional differences from iQ-F Series
Please refer to the below Technical bulletin for the functional differences between the MX-F model and the iQ-F series. [Technical bulletin] ・Differences ... More Details >>
- No:44979
- Release Date:2025/06/18 14:38
- Category: MELSEC MX Controller MX-F Model
-
SB/SW refresh device setting with CC-Link
SB/SW uses 512 points of refresh devices. More Details >>
- No:23081
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Cause to turn on the ERR LED of a CC-Link master module
All stations communication error of a slave station.When POWER of the slave station is off, check if 24 V DC has been supplied.When POWER is on, check the st... More Details >>
- No:23079
- Release Date:2018/09/03 17:31
- Category: Network related products