FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MX Component Version 4's compatibility with Visual C++ 6.0
MX Component Version 4 does not support Visual C++ 6.0. More Details >>
- No:22913
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
I cannot place a main base unit in a module configuration diagram with GX Works3.
You may have already placed a main base unit in the module configuration diagram. Scroll up or down in the module configuration diagram and check if a main ... More Details >>
- No:22487
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:37
- Category: MELSEC iQ-R Series
-
Regarding the terminal arrangement of I/O module (extension connector type)
The connector's terminal arrangement is the smaller number on the left and larger number on the right. More Details >>
- No:39329
- Release Date:2023/01/12 16:57
- Category: MELSEC iQ-F Series , I/O Module
-
External appearance of the F2-40BL
Some of the F2-40BL batteries installed to a programmable controller are mounted on the printed circuit board. The separately available F2-40BL batteries (sp... More Details >>
- No:24771
- Release Date:2019/02/27 15:17
- Category: MELSEC-F Series , Accessories
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio.Example) For Q06HCPU with power-on time ratio of 50... More Details >>
- No:22523
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
How to check the error history of the QJ71C24N with GX Developer
You can check the error history in the module detailed information in the system monitor of GX Developer. More Details >>
- No:23064
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to display the multiple CPU function setting window of MELSEC iQ-R series CPU modules
You can display the setting window in the multiple CPU setting of system parameters. <Multiple CPU setting> [Navigation Window]-> [Parameter]-&g... More Details >>
- No:22484
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:13
- Category: MELSEC iQ-R Series
-
Cascade connections between hubs in the CC-Link IE Field Network
UP to 20 levels of cascade connections can be made. More Details >>
- No:23051
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:46
- Category: Network related products