Regarding editing device comments in the device usage list
Supported since GX Works3 Ver. 1.095Z, you can edit device comments from the device usage list. More Details >>
- No:40038
- Release Date:2023/08/24 15:44
- Category: MELSEC iQ-F Series , Engineering Software
-
Limitation on the number of levels of cascade connections when QJ71E71-100 is used
If a repeater hub is used, 10BASE-T allows a maximum of four levels of cascade connections and 100BASE-TX allows a maximum of two levels of cascade connectio... More Details >>
- No:23040
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
- Category: Network related products
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
They can be used simultaneously when I/O signals are not overlapped. The overlap of signals are checked automatically when a user select functions in the bui... More Details >>
- No:22816
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
- Category: MELSEC iQ-F Series , Network/Communication
-
Whether or not totem pole output type encoders are connected
Totem pole output encoders cannot be connected to QD62.The following types of encoders can be connected.- Open collector output type encoders- CMOS level vol... More Details >>
- No:22641
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Regarding use of extended extension cable
Extended extension cable for MX-F Model: FX5-30 EC/FX5-65 EC can be used. However, only one extended extension cable is allowed per system. *Extended extens... More Details >>
- No:44985
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model