FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Accessing file registers from the built-in Ethernet port QCPU using A-compatible 1E frames
The QnUDE(H)CPU modules with serial numbers with upper 5 digits of "14112" or later indicate compatibility with the function. The accessible device range is ... More Details >>
- No:22645
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It means that in an ambient temperature of 25 degrees Celsius, an error per day falls within the range of "delay of 2.57s" to "advance of 5.27s". "TYP.+2.22... More Details >>
- No:22651
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:53
- Category: MELSEC-Q Series
-
Ladder programs for GX Configurator-FL
When GX Configurator-FL is used, programs for initial settings and cyclic data reading and writing are not needed. More Details >>
- No:22658
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Accessible numbers of devices in one message are shown below.- 2000 coils and inputs for reading- 125 input registers and holding registers for reading- 1968... More Details >>
- No:22668
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
USB cable type for CPU modules
It is the miniB-type. More Details >>
- No:22677
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Execution in a multi task environment
The QBF_Open ( ) function or mdOpen ( ) function is required for every task. Do not share the PATH acquired using an Open function with other tasks.Also, exe... More Details >>
- No:22678
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Measuring temperatures with programmable controllers
The following four models are available for the purpose.- Q64TD- Q64TDV-GH- Q68TD-G-H01- Q68TD-G-H02 More Details >>
- No:22684
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
A/D conversions performed by Q64AD/Q68ADV/Q68ADI
(1) Sampling processing - Without the temperature drift compensation function Processing time = Number of channels usedx 80 (us/1 channel) - With the t... More Details >>
- No:22705
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:34
- Category: MELSEC-Q Series
151-160 of Total 1123