FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Use of an A-compatible 1E frame for the built-in Ethernet port of the built-in Ethernet port QCPU
Check the serial number of the built-in Ethernet port QCPU in use. The Built-in Ethernet port QCPU modules with serial numbers with upper 5 digits of "13102"... More Details >>
- No:22676
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
FNC connector pin layout in L series I/O module and Q series I/O module
Yes. They have the same pin layout. More Details >>
- No:22774
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to use LCPU connector terminals
The LCPU connector terminals can be used as terminals for built-in I/O function. The setting of the built-in I/O function can be configured with the paramete... More Details >>
- No:22796
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Number of data sampling points in LCPU logging function
Up to 1280 points. (128 points per setting, and up to 10 data logging settings) More Details >>
- No:22805
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Regarding parameter setting for FX5-CCL-MS
It is possible to set the basic/application settings in a program by selecting the parameter setting method to "Program." Even if set by "program" is select... More Details >>
- No:39367
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Maximum apparent power of the power supplies of Q00JCPU and Q00UJCPU
Both are 105 VA. More Details >>
- No:22538
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
11-20 of Total 1123