FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How to set the numbers of occupied stations for CC-Link local stations
Set the number of occupied stations for a CC-Link local station using the programming tool, GX Developer or GX Works2. Set the number for "Number of Occupied... More Details >>
- No:22980
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Intelligent Buffer Select of the CC-Link parameter
Set the size of buffer memory used for transient transmission (by dedicated instructions) to local stations, the standby master station, and intelligent devi... More Details >>
- No:22977
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Reading a project in another format
To open a project created with GX Developer, select [Project]-> [Import file]-> [Import from xxxx format file] from the menu in GX Works2. More Details >>
- No:22952
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:56
- Category: Engineering Software
-
Writing QJ71C24N's parameters in GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22872
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The built-in I/O functions are standard functions of the L series CPU. Combining these functions flexibly achieves various controls with lower cost, eliminat... More Details >>
- No:22806
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Storing the data logging setting to an SD memory card in LCPU
In the write logging setting, choose [Online] and [Write Logging Setting], and set the target memory to SD memory card. More Details >>
- No:22758
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SD1282 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1282 (Open completion signal) correspond to the connection numbers 1 to 16. When the open processing is completed, ... More Details >>
- No:22751
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Use SP.FWRITE instruction to save the data to an SD memory card in CSV format. More Details >>
- No:22727
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series