Connected position of branch module and extension module
The position to connect the branch module and extension module is as follows. More Details >>
- No:22814
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:27
- Category: MELSEC-L Series
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Languages supported by structured projects
Yes. More Details >>
- No:22855
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Program by program difference in comments on display
There are two types of device comments: "global device comment" and "local device comment". Device comments can be displayed in the ladder editor and Zoom... More Details >>
- No:22868
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:40
- Category: Engineering Software
-
Local device comments can be read if the comment file in which the local device comments are stored is written to the CPU module. More Details >>
- No:22869
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Writing QJ71C24N's parameters in GX Works2
The switch setting is written when CPU module's parameters are written. The settings of "Various Control Specifications" are written when intelligent functio... More Details >>
- No:22872
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
- Category: Engineering Software