Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Software to be supplied with GX Works3
GX Works2 and GX Developer are supplied with GX Works3. When installing GX Works3, you can select whether to install GX Works2 and GX Developer together. More Details >>
- No:22463
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:14
- Category: MELSEC iQ-R Series
-
Mounting Q series modules on a MELSEC iQ-R series base unit
You cannot mount Q series modules on a MELSEC iQ-R series base unit. Use an RQ extension base unit (RQ65B, RQ68B, or RQ612B). You cannot mount some modules... More Details >>
- No:22466
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:58
- Category: MELSEC iQ-R Series
-
Models of extended SRAM cassettes that can be used with MELSEC iQ-R series CPU modules
You can use "NZ2MC-1MBS", "NZ2MC-2MBS", "NZ2MC-4MBS", "NZ2MC-8MBS", "NZ2MC-16MBS",and "NZ2MC-8MBSE". You cannot use extended SRAM cassettes for the high-spe... More Details >>
- No:22468
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:36
- Category: MELSEC iQ-R Series
-
Those displayed under COMMENT are common comments, and others are program comments.When there are multiple programs in a project, a common comment applies to... More Details >>
- No:22540
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Network No., Group No., and Station No. in Network Parameter
- Network No. is a number assigned to identify each network when multiple networks are configured. Each network No. must be unique. - Group No. is a num... More Details >>
- No:22550
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:48
- Category: MELSEC-Q Series
-
MODBUS(R) interface module's involvement in master and slave stations
Intelligent function module settings allow them to be set in both master and slave stations. More Details >>
- No:22637
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
We do not guarantee the operation of a system that involves cross cable connections. More Details >>
- No:22679
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series