FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding the number of FX5-4A-ADP connections
Up to 4 FX5-4A-ADPs can be connected to an FX5U/FX5UC/FX5S CPU module. To connect 3 or more FX5-4A-ADPs, the FX5-4A-ADP must have a serial number S/N: 224... More Details >>
- No:39348
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding input of Differential Driver Output Type
It does not. The built-in high-speed counter function of the FX5U/FX5UC CPU module does not support DC5V input. DC5V input can be achieved by adding BUS con... More Details >>
- No:39350
- Release Date:2023/01/12 17:09
- Update:2025/03/07 13:25
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding the communication speed of FX5-CCLGN-MS
The FX5-CCLGN-MS firmware version 1.010 or later supports a communication speed setting of 100 Mbps. More Details >>
- No:39358
- Release Date:2023/01/12 17:09
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Instruction description help in GX Works3
You can open the descriptions for each instruction by moving the cursor to the target instruction and pressing F1. You can also hover the cursor over it and ... More Details >>
- No:39366
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding parameter setting for FX5-CCL-MS
It is possible to set the basic/application settings in a program by selecting the parameter setting method to "Program." Even if set by "program" is select... More Details >>
- No:39367
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding FX5-CCLIEF Maximum Link Points
The maximum link points of the FX5-CCLIEF are 384 points each for RX/RY and 1024 points each for RWw/RWr. More Details >>
- No:40020
- Release Date:2023/08/24 14:31
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the FX5UC CPU module/Intelligent Function module Power Cable
The model name of the power cable is FX2NC-100MPCB. It is included with the FX5UC CPU module and intelligent function modules that require power from the pow... More Details >>
- No:40021
- Release Date:2023/08/24 14:31
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication , Motion/Positioning , Analog
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Device Memory Export/Import
Imports are not supported. Only exports are supported. More Details >>
- No:40027
- Release Date:2023/08/24 14:38
- Category: MELSEC iQ-F Series , Engineering Software
341-350 of Total 1082