Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
In order for the programmable controller to receive input pulses completely, the ON duration and OFF duration of inputs in the programmable controller requir... More Details >>
- No:24704
- Release Date:2019/02/27 09:00
- Category: MELSEC-F Series , Main Unit , High-Speed Counting
-
Programming software and tool for the FX2N-10GM/FX2N-20GM
Use the "FX-PCS-VPS/WIN" software for personal computer or the "E-20TP-SET0" handy programming panel. More Details >>
- No:25014
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Accessories
-
Regarding the text color of file names
The data name shown in "red" means "unconverted data" or "unused data before conversion." Data name displayed in 'light blue' means "unused". If a conversio... More Details >>
- No:39345
- Release Date:2023/02/15 10:06
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding checking latch settings
You can find it in the Advanced Settings section of GX Works3. Use the following procedure to display the Device (High Speed) settings. From the GX Wor... More Details >>
- No:44364
- Release Date:2024/03/27 16:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the frequency of high-speed counters
The maximum frequency of the FX5U/FX5UC CPU module is 200kHz and the maximum frequency of the FX5S/FX5UJ CPU module is 100 kHz. More Details >>
- No:22312
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:18
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding how to check the date of manufacture
You can check the LOT. on the front of the controller or the nameplate on the right side. Verifying on the front of the Controller Nameplate verification... More Details >>
- No:44968
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding the type of battery which can be used with the CPU module.
FX3U-32BL can be used. The battery is not included with the CPU modu... More Details >>
- No:22285
- Release Date:2018/08/30 13:55
- Category: MELSEC iQ-F Series , Option , CPU Module
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Regarding Data Logging File Storage Format
It's possible. For the firmware and software versions of the corresponding CPU units, refer to the respective manuals. More Details >>
- No:39308
- Release Date:2023/02/13 16:44
- Update:2023/02/14 09:01
- Category: MELSEC iQ-F Series , CPU Module