Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Accessories of the FX3UC-16MR/DS-T and the FX3UC-16MR/D-T
The "FX2NC-100MPCB" power supply cable for main unit is provided with the FX3UC-16MR/DS-T. The "FX2NC-100MPCB" and the "FX2NC-100BPCB" power supply cable for... More Details >>
- No:25005
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Main Unit , Accessories
-
FX series products that support CC-Link Ver.2.0
FX3U-16CCL-M CC-Link master block and the FX3U-64CCL CC-Link interface block supports CC-Link Ver.2.0. Both blocks are dedicated for the FX3 series. More Details >>
- No:25004
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Operation processing time of the programmable controller
The constant operation processing time can be achieved by using constant scan mode. Refer to the programming manual of the programmable controller used. More Details >>
- No:24997
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Instruction execution complete flag
When a flag contact is not programmed directly under the instruction to be checked, the flag may be turned off depending on the execution status of another i... More Details >>
- No:24988
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Main Unit
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Connection of the FX3G series and the GT1020/GT1030 series (5 V type)
Only one GT1020/GT1030 series (5 V type) can be connected to the FX3G series. To connect two GOTs, select the GT1020/GT1030 series (24 V type). More Details >>
- No:24969
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit
-
Yes, it is possible. To set the programmable controller to RUN again, while the programmable controller is stopped, set the built-in RUN/STOP switch as follo... More Details >>
- No:24965
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Main Unit