FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Temperature input modules that can be used with FX3G series
FX3U-4AD-PT-ADP (Pt100 temperature sensor input special adapter), FX3U-4AD-PTW-ADP (Pt100 temperature sensor input special adapter), and FX3U-4AD-TC-ADP (K/J... More Details >>
- No:24993
- Release Date:2019/04/23 10:38
- Category: MELSEC-F Series , Analog Control
-
Changing the JOG speed in the FX3U-20SSC-H
Since the JOG speed is the positioning parameter, turn off and on the positioning parameter enable command (X-axis: BFM#519.b4, Y-axis: BFM#619.b4) to enable... More Details >>
- No:24987
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
Assignment of direction signals during positioning
Any number can be assigned. More Details >>
- No:24975
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Positioning Control
-
Pulse output type of the FX3U-1PG pulse output block
It is transistor output. Transistor output specifications are as follows. ・ Rated load voltage 5 to 24 V DC ・ Maximum load current 20 mA or lower More Details >>
- No:24972
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
It is not possible to extend the length of the extension cable to over 65cm. Place the main unit separately by using the parallel link or N:N Network functio... More Details >>
- No:24941
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Accessories
-
Drive products (servo amplifiers) that can be connected to the FX3U-1PG pulse output block
Servo amplifiers, such as MR-J4-□A and MR-JN-□A, that support pulse train input can be connected. For connectable drive products, such as servo amplifiers, ... More Details >>
- No:24940
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
One FX3U-ENET-ADP can be connected at the last stage (left end) of adapters for the FX3UC series. *The FX3U-ENET-ADP is a communication special adapter and ... More Details >>
- No:24932
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Adding two channels of the RS-232C port in the FX3G series
Select the 40-point or 60-point type FX3G series main unit. In this case, two FX3G-232-BDs can be connected. When FX3G-CNV-ADP is used, anFX3U-232ADP can be ... More Details >>
- No:24926
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
371-380 of Total 1082