Number of records in LCPU logging function
It is the number of data collected before and after a trigger occurrence. More Details >>
- No:22794
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Retention of auto tuning setting value for temperature control module
Use the automatic backup setting. While "1: enabled" is set in the CH[] automatic backup setting after auto tuning of PID constants in the buffer memory (Un\... More Details >>
- No:22795
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Support for Q series RS-232 cable
Yes. More Details >>
- No:22803
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
An error occurs and CPU will stop. Install the END cover and reset the CPU module. More Details >>
- No:22817
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Program by program difference in comments on display
There are two types of device comments: "global device comment" and "local device comment". Device comments can be displayed in the ladder editor and Zoom... More Details >>
- No:22868
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:40
- Category: Engineering Software
-
Function blocks of GX Developer and GX Works2
The same function blocks can be created and used. More Details >>
- No:22887
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Necessity for GX Configurator-SC
The serial communication modules do not require GX Configurator-SC. However, we recommend GX Configurator-SC as it reduces man-hours. (1) The predefined ... More Details >>
- No:22905
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:33
- Category: Engineering Software
-
Reference manuals for programming for FX programmable controllers in ST language
The following shows the manuals for programming in ST language. - GX Works2 Beginner's Manual (Structured Project) - GX Works2 Version 1 Operating Manual... More Details >>
- No:22959
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:16
- Category: Engineering Software
-
Necessity of terminating resistors in CC-Link communication
No, it is unnecessary. Terminating resistors are only required at both ends of the network. More Details >>
- No:22966
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
- Category: Network related products