How to check link errors in CC-Link slave stations
The data link status is stored in SW80 to SW83.Each bit corresponds to a station number and a bit turns ON if the corresponding station causes a data link er... More Details >>
- No:23031
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MX Component Version 4's compatibility with Visual Studio 2008
Yes. More Details >>
- No:22879
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Checking the amount of free space of the memory in GX Developer/GX Works2
Select [Tool] -> [Confirm Memory Size] to check the amount. More Details >>
- No:22851
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Uninstalling GX Works2 before the installation of GX Works3
You do not have to uninstall GX Works2 before installing GX Works3. You can install GX Works3 into your computer where GX Works2 has already been installed. More Details >>
- No:22464
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:20
- Category: MELSEC iQ-R Series
-
Software to be supplied with GX Works3
GX Works2 and GX Developer are supplied with GX Works3. When installing GX Works3, you can select whether to install GX Works2 and GX Developer together. More Details >>
- No:22463
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:14
- Category: MELSEC iQ-R Series
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding compatible version of CANopen communication function for PDO communication
It is necessary to use the following CPU module, FX5-CCLGN-MS, GX Works3 versions. FX5-CCLGN-MS・・・1.020 or later FX5U/FX5UC CPU module ・・・1.260 or later ... More Details >>
- No:44473
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Project verification
You can verify from GX Works3 Project - Verify with PLC. Manual GX Works3 Operating Manual More Details >>
- No:40028
- Release Date:2023/08/24 14:39
- Category: MELSEC iQ-F Series , Engineering Software