Method to prevent the BAT.LED from turning on
To prevent an LED from turning on when an error occurs, set 0 to the relevant factor number setting area (4 bits for each) in SD207 to SD209. To disable the ... More Details >>
- No:22754
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22733
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
QnA-compatible 3E frame command for built-in Ethernet port in LCPU
The built-in Ethernet port in the L series CPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are ... More Details >>
- No:22726
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Deleting GX Developer when installing GX Works2
GX Developer does not need deleting when GX Works2 is installed. More Details >>
- No:22670
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The communication can be established using the following methods. - Using the socket communication function of both CPU modules - Using the simple PLC comm... More Details >>
- No:22664
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:51
- Category: MELSEC-Q Series
-
Production of Q61P-A1 and Q61P-A2
They have gone out of production. However, Q61P, a succeeding model, can be used in the same way. More Details >>
- No:22655
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting of Q series registers whose data is held when a power failure occurs
Assign data registers (D) to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> "Device Setting" window) to hold the data when a po... More Details >>
- No:22601
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
"No administrator authority" warning displayed in MX Component
The user account control (UAC) setting needs to be changed.For more details, refer to Appendix 8.2 of the following manual.- MX Component Version 3 Operating... More Details >>
- No:22590
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series