Settings required for transient transmission
The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
- Category: Network related products
-
How to make the expanded cyclic setting for CC-Link local stations
Make the expanded cyclic setting for a CC-Link local station using the programming tool, GX Developer or GX Works2. Follow the procedure below. (1) Set th... More Details >>
- No:23030
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:17
- Category: Network related products
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Using special blocks (extension blocks) away from a main unit
To use the special blocks away from the main unit, connect them with the FX0N-30EC/FX0N-65EC extension cable and the FX2N-CNV-BC connector conversion adapter. More Details >>
- No:24966
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Accessories
-
Regarding maximum number of connected stations for built-in CC-Link IE TSN
The maximum number of stations that can be connected in the network depends on the model name of the MX-F model. ・MXF100-16 N32/P32: Up to 46 stations ・MXF... More Details >>
- No:44973
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
- Category: MELSEC MX Controller MX-F Model
-
Regarding maintaining device back up
Battery: FX3U-32BL is not required for device back up.The battery is used to store clock data. More Details >>
- No:44976
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Local devices are devices which can be independently used for each program.When multiple independent programs are executed, using local devices allows progra... More Details >>
- No:22531
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Reading file registers simultaneously with the program, parameters, and other data in GX Works2
No. Switch the target memory for PLC Data and read the file registers alone. More Details >>
- No:22616
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The communication can be established using the following methods. - Using the socket communication function of both CPU modules - Using the simple PLC comm... More Details >>
- No:22664
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:51
- Category: MELSEC-Q Series
-
Change timing of the status of A/D conversion module's I/O signals
(1)If the A/D conversion enable signal is kept ON, conversion processing is kept performed. Once conversion processing is successfully performed, A/D conve... More Details >>
- No:22710
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:12
- Category: MELSEC-Q Series