Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
- Category: Network related products
-
The conversion speed is 20 microseconds per channel. More Details >>
- No:22826
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
MC protocol compatibility of the built-in Ethernet port
The built-in Ethernet port is not compatible with a 4E frame. Use a QnA-compatible 3E frame. More Details >>
- No:22732
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
What to do in the case of the error "A default router IP address needs to be set."
When having access bypassing a router, enter only the IP address.The subnet mask pattern is not required to be entered because GX Works2 or GX Developer auto... More Details >>
- No:22605
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:06
- Category: MELSEC-Q Series
-
Socket communication with the built-in Ethernet port of a CPU module
The communication between programmable controllers can be established using the socket communication function instructions. More Details >>
- No:22596
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Auto refresh setting in GX Configurator -MB
Auto refresh setting is for storing the buffer memory data of a MODBUS (R) interface module to specified devices of a CPU module and for storing device data ... More Details >>
- No:22573
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
There are three types of parameters in GX Works3; "System parameter", "CPU parameter", and "Module parameter". You can set the following items with each par... More Details >>
- No:22483
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:08
- Category: MELSEC iQ-R Series
-
[F2-40BL] F1/F1J/F2 series, FX1/FX2/FX2C/FX2N series, and FX-20GM/E-20GM [FX1N-BAT] FX1N series* [FX3U-32BL] FX3G*/FX3GC/FX3U/FX3UC series and FX-30P [FX2N... More Details >>
- No:22282
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication