I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Switch settings of intelligent function module and I/O assignment settings (GX Works2)
Those switch settings are connected with each other. The switch setting of intelligent function module settings are easier to set. More Details >>
- No:22883
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with LJ71E71-100
GX Developer does not support LJ71E71-100. Use GX Works2. More Details >>
- No:22911
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Programming for FX programmable controllers in ST language
You can create a program with "GX Works2" of MELSOFT applications. More Details >>
- No:22960
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Applicable size for plug-in connector socket block on QJ71C24N-R4
Use the plate terminal packaged with the module. The size of the plate terminal is 1.0 mm wide with a thickness of 0.8 mm. More Details >>
- No:23043
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Station number settings for MELSECNET/H networks
A station number can be skipped by setting the station as a reserved station. More Details >>
- No:23045
- Release Date:2018/09/03 17:31
- Category: Network related products
-
SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Yes. You can check the servo status through the following monitor data. • "[Md.108] Servo status 1" • "[Md.125] Servo status 3" (QD77MS, LD77MS, LD77MH) ... More Details >>
-
Terminal layout of the FX3U-1PG and FX2N-1PG pulse output blocks
Yes, they have the same terminal layout. More Details >>
- No:24900
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Positioning Control