FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Processing time of when multiple programs are executed with a MELSEC iQ-R series CPU module
When multiple programs are executed, the processing time (program switching time) becomes "Number of program files × 0.9 [us]". More Details >>
- No:22491
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:49
- Category: MELSEC iQ-R Series
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Follow the procedure below to insert a high-speed timer.- Click the Coil button on the toolbar or press the function key F7, then enter "HT[ ] K[ ]".- Click ... More Details >>
- No:22528
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Network No., Group No., and Station No. in Network Parameter
- Network No. is a number assigned to identify each network when multiple networks are configured. Each network No. must be unique. - Group No. is a num... More Details >>
- No:22550
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:48
- Category: MELSEC-Q Series
-
Auto refresh setting in GX Configurator -MB
Auto refresh setting is for storing the buffer memory data of a MODBUS (R) interface module to specified devices of a CPU module and for storing device data ... More Details >>
- No:22573
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
What to do in the case of the error "A default router IP address needs to be set."
When having access bypassing a router, enter only the IP address.The subnet mask pattern is not required to be entered because GX Works2 or GX Developer auto... More Details >>
- No:22605
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:06
- Category: MELSEC-Q Series
-
Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Cost of runtime licenses for VxWorks
The cost is included in the price of C Controller modules. Extra payment is not required. More Details >>
- No:22653
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
QnA-compatible 3E frame command for built-in Ethernet port in LCPU
The built-in Ethernet port in the L series CPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are ... More Details >>
- No:22726
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
571-580 of Total 1123