Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
-
Maximum length of input wiring
Although it depends on the operating environment, wiring within 20 m is generally recommended. More Details >>
- No:24949
- Release Date:2019/04/18 14:29
- Category: Main Unit
-
Use of a commercial SD memory card in L series logging function
Yes. Recommended products are listed in the technical bulletin FA-A-0078. More Details >>
- No:22753
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:25
- Category: MELSEC-L Series
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
File switching timing of L series logging function
No. More Details >>
- No:22809
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Whether or not MC protocol frames can be used after A1SJ71UC24 is replaced with QJ71C24N
The QJ71C24N series modules can be accessed using A-compatible 1C frames, but the following restrictions are imposed. The access is limited to the devices wi... More Details >>
- No:22970
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master module settings
If each master module controls their own CC-Link networks, all master modules can be set as station 0 even though they are controlled by the same CPU. More Details >>
- No:23008
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Assignment for connecting two CC-Link remote input modules (16-point type) (Remote net Ver.1 mode)
X devices will be assigned as follows. (With this setting, 32 points are occupied per station.) - Station No. 1: X100 to X11F -Station No. 2: X120 to X13... More Details >>
- No:23082
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:15
- Category: Network related products
-
Yes. You can check the servo status through the following monitor data. • "[Md.108] Servo status 1" • "[Md.119] Servo status 2" • "[Md.125] Servo status 3... More Details >>
-
Changing the JOG speed in the FX3U-20SSC-H
Since the JOG speed is the positioning parameter, turn off and on the positioning parameter enable command (X-axis: BFM#519.b4, Y-axis: BFM#619.b4) to enable... More Details >>
- No:24987
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control