File names can not be changed. It is fixed to EXFILER.ERD. More Details >>
- No:39296
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module
-
The FX2N-16CCL-M cannot be set as the master station in the parameter setting. Use the FROM/TO instructions and setin the program. More Details >>
- No:25001
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Network/Communication
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Input of the R device of the FX3U series in the FX-20P
Since the FX3U series does not support the FX-20P, available device ranges are within the range of the FX2N. ("R" devices do not exist in the FX2N.) The ha... More Details >>
- No:24989
- Release Date:2019/04/23 10:37
- Category: MELSEC-F Series , Accessories
-
Connecting local stations to the FX3U-16CCL-M
No, local stations cannot be connected to the FX3U-16CCL-M. Remote I/O stations, remote device stations, and intelligent device stations can be connected to... More Details >>
- No:24791
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Network/Communication
-
Data that can be stored in a memory cassette (FX3U/FX3UC)
The device memory data cannot be stored in a memory cassette. In the FX3U/FX3UC series, a part of device memory data can be latched using a battery. The de... More Details >>
- No:24789
- Release Date:2019/02/28 09:07
- Category: MELSEC-F Series , Accessories
-
Reading a project in another format
To open a project created with GX Developer, select [Project]-> [Import file]-> [Import from xxxx format file] from the menu in GX Works2. More Details >>
- No:22952
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:56
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Basic .NET 2003
MX Component Version 4 does not support Visual Basic .NET 2003. More Details >>
- No:22899
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Function blocks of GX Developer and GX Works2
The same function blocks can be created and used. More Details >>
- No:22887
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Local device comments can be read if the comment file in which the local device comments are stored is written to the CPU module. More Details >>