FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
MC protocol supported by the FX3U-ENET-L
The frame typesupported byMC protocol is equivalent to A-compatible 1E frame. More Details >>
- No:24702
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Network/Communication
-
Executing the QJ71C24N's pre-defined protocol support function
Executing the CPRTCL instruction (dedicated instruction) executes a specified protocol. More Details >>
- No:23004
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for QJ71C24N
A terminating resistor must be connected to the interface in order to reduce signal reflections thus preventing the signal instabilities. More Details >>
- No:22982
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Retention of auto tuning setting value for temperature control module
Use the automatic backup setting. While "1: enabled" is set in the CH[] automatic backup setting after auto tuning of PID constants in the buffer memory (Un\... More Details >>
- No:22795
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to increase file register capacity
In LCPU, file register capacity depends on CPU. The number of file register points cannot be increased. (A file register cannot be set on an SD memory card.)... More Details >>
- No:22766
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Replacing an AnS I/O module with a Q I/O module
Yes. More Details >>
- No:22717
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
CF cards supported by the high speed data logger module
For applicable CF cards, refer to the latest version of the following manual.- High Speed Data Logger Module User's Manual- SH-080818ENG- 2.3 Connection Syst... More Details >>
- No:22607
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
"No administrator authority" warning displayed in MX Component
The user account control (UAC) setting needs to be changed.For more details, refer to Appendix 8.2 of the following manual.- MX Component Version 3 Operating... More Details >>
- No:22590
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It is an embedded RTOS (real-time OS) developed by Wind River, which is proven worldwide as reliable and stable.The version of the operation system installed... More Details >>
- No:22544
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Clearing the battery error without resetting the CPU module
It is impossible. Battery replacement is essential in clearing the battery error and the power of the programmable controller must be turned off before the... More Details >>
- No:22510
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:27
- Category: MELSEC-Q Series
671-680 of Total 1110