Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Clearing the battery error without resetting the CPU module
It is impossible. Battery replacement is essential in clearing the battery error and the power of the programmable controller must be turned off before the... More Details >>
- No:22510
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:27
- Category: MELSEC-Q Series
-
Make sure to turn off the power of the programmable controller before replacing the battery. Replacing the battery while the power of the programmable con... More Details >>
- No:22509
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:24
- Category: MELSEC-Q Series
-
How to display the parameter setting window for a programmable controller with GX Works3
You can display the setting window from a module configuration diagram or system parameters. <Displaying the setting window from a module configuration... More Details >>
- No:22498
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:10
- Category: MELSEC iQ-R Series
-
Interrupt program priority setting of MELSEC iQ-R series
You can set interrupt priorities 5 to 7 for interrupt pointers (I0 to I15, I50 to I1023) from the module. You cannot change the priorities of interrupt poin... More Details >>
- No:22482
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:05
- Category: MELSEC iQ-R Series
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
- Category: MELSEC iQ-R Series
-
When the block number of the file register (R) is saved and stored, the overhead time becomes 35.9 [us]. When the number of the file register is not saved o... More Details >>
- No:22465
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:57
- Category: MELSEC iQ-R Series
-
Do not use vacant terminals. More Details >>
- No:25003
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series