The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
- Category: Network related products
-
Reception data read request signal of QJ71C24N not turn ON
The default receive complete code is CR+LF (0DH, 0AH). The default received data count is 511 words. Hence, at their defaults, Reception data read request si... More Details >>
- No:22984
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:22
- Category: Network related products
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
- Category: Engineering Software
-
Displaying devices in GX Works2
Yes. The device use list also displays the devices used for specifying digits, such as "K4M0" (including M1, M2, or others). More Details >>
- No:22942
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Studio 2005
Yes. More Details >>
- No:22914
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Identifying an SFC program block in execution
Specify a block in the cross reference list and search it. (For block 1, search BL1, for example.) More Details >>
- No:22907
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
How to paste values in the device batch monitor window into an Excel sheet
Copy and paste operations cannot be carried out for values displayed in the device batch monitor window. To paste the values into an Excel sheet, read the d... More Details >>
- No:22888
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:54
- Category: Engineering Software
-
Maximum number of modules to be connected to L26CPU-(P)BT
Up to 40 modules. When the branch module and extension module are used, use L26CPU-(P)BT CPU modules whose first 5 digits of the serial number are "13072" or... More Details >>
- No:22813
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Behavior of sequence program in event of momentary power failure in LCPU
(1) When it happened no longer than the allowable momentary power failure time. The module records an error log and suspends the operation processing. Ho... More Details >>