FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
MX Component Version 4's compatibility with the L series CPU
MX Component Version 4 supports the L series CPU. More Details >>
- No:22867
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Opening function block and Structured Text projects in GX Works2
The project can be read by selecting "Open other project" in GX Works2. - Function names for the GX Developer's Structured Text are different from those of ... More Details >>
- No:22864
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:28
- Category: Engineering Software
-
Installing MX Component Version 3 and 4
No, please install only either of the two. More Details >>
- No:22841
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
A password can be set. - Use the file password 32 function.- Number of characters: 4 to 32 (alphanumeric and special characters, case-sensitive)- Disabled op... More Details >>
- No:22810
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The built-in I/O functions are standard functions of the L series CPU. Combining these functions flexibly achieves various controls with lower cost, eliminat... More Details >>
- No:22806
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The heater disconnection detection function monitors the heater current on the transistor output. If no current flows when the transistor is ON, it is consi... More Details >>
- No:22773
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:58
- Category: MELSEC-L Series
-
Operation during power failure
It stops during execution. More Details >>
- No:22764
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to suppress the instability of digital-converted output values
(1) Use separate cables for the AC control circuit and the external input signals of an analog input module to avoid the influence of the AC side surges an... More Details >>
- No:22709
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:11
- Category: MELSEC-Q Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
811-820 of Total 1123