Regarding using the MQTT Communication function in a local environment
Yes, you can use MQTT communication function even in the local network by preparing a personal computer with MQTT broker such as Eclipse Mosquitto installed.... More Details >>
- No:44367
- Release Date:2024/03/27 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the differences between the FX5-2HC/ES and the conventional FX3U-2HC input formats
The FX5-2HC/ES supports differential line drivers (5 V) only. The FX3U-2HC supports open collectors (24 V/12 V/5 V) and differential line drivers (5 V). ... More Details >>
- No:44338
- Release Date:2024/03/26 09:02
- Category: MELSEC iQ-F Series , High-Speed Counter
-
The following points are different for the iQ-F series. ・Error History If the FX5 CPU Module is turned off, the error history is cleared. ・Setting detail... More Details >>
- No:44335
- Release Date:2024/03/20 13:21
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding differences in simple CPU communication functions
There is no difference in functionality, only in the number of connections. More Details >>
- No:40039
- Release Date:2023/08/24 15:44
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the number of FX5-4A-ADP connections
Up to 4 FX5-4A-ADPs can be connected to an FX5U/FX5UC/FX5S CPU module. To connect 3 or more FX5-4A-ADPs, the FX5-4A-ADP must have a serial number S/N: 224... More Details >>
- No:39348
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the difference between the RS-485 expansion adapter and the extension board
The difference is the maximum transmission distance and the presence/absence of insulation (between the communication line and the CPU). ・Expansion Adapter ... More Details >>
- No:39315
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Reflecting the changes in the communication setting
Power off and on the programmable controller again after the communication setting is changed. More Details >>
- No:25006
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Engineering Software , Main Unit