Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
- Category: Network related products
-
Reading a project in another format
To open a project created with GX Developer, select [Project]-> [Import file]-> [Import from xxxx format file] from the menu in GX Works2. More Details >>
- No:22952
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:56
- Category: Engineering Software
-
Index modification in function blocks
Index modification cannot be used for labels. To set index modification, use actual devices as the target devices. More Details >>
- No:22930
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Q6BAT. More Details >>
- No:22780
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Difference between L02CPU-P and L02CPU
In L02CPU-P, the general-purpose output of the built-in I/O is source type. In L02CPU, the general-purpose output of the built-in I/O is sink type. More Details >>
- No:22743
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
Change timing of the status of A/D conversion module's I/O signals
(1)If the A/D conversion enable signal is kept ON, conversion processing is kept performed. Once conversion processing is successfully performed, A/D conve... More Details >>
- No:22710
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:12
- Category: MELSEC-Q Series
-
Runtime license for MX Component
A runtime license is required for all personal computers on which MX Component operates. More Details >>
- No:22657
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Regarding built-in ethernet port differences
Port 1 becomes the CC-Link IE TSN, and port 2 can be switched between Ethernet and CC-Link IE TSN. To use port 2 as an Ethernet port, set the Built-in Netwo... More Details >>
- No:44969
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model