Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to use L series extension modules
The extension module is used to configure the extension block when 10 modules or more are mounted to LCPU. Connect the branch module and the extension module... More Details >>
- No:22738
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
- Category: MELSEC-L Series
-
MC protocol compatibility of the built-in Ethernet port
The built-in Ethernet port is not compatible with a 4E frame. Use a QnA-compatible 3E frame. More Details >>
- No:22732
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
- Category: MELSEC-Q Series
-
There are no settings for deleting the network number and PC number. More Details >>
- No:22708
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to change the type of statement in GX Developer
Select [Search/Replace] -> [Replace statement/note type] from the menu and select "Change in PLC". More Details >>
- No:22647
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Software required for MX Sheet
MX Component and EXCEL are required. More Details >>
- No:22646
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series